Vendeur: Medansh

Electronic Intubation Manikin with Feedback System

187,02 €364,13 €48% OFF
Quantité

Détails du produit

Electronic Tracheal Intubation Manikin with Real-Time Feedback

The Electronic Tracheal Intubation Manikin with Real-Time Feedback is designed for medical colleges, nursing institutes, hospitals, anaesthesia departments and clinical skills laboratories. This intubation manikin provides a realistic adult head, neck and upper-torso platform for practising airway assessment and endotracheal tube placement.

The model recreates important oral and airway structures required during intubation training. In addition, its electronic system provides interactive guidance during selected practice scenarios. Therefore, learners can identify technique errors and improve tube direction, hand control and procedure order in a safe setting.

The airway section includes a simulated mouth, tongue, throat and vocal-cord region. Moreover, the model supports different levels of intubation difficulty for structured skill development. As a result, instructors can use it for demonstrations, repeated practice and clinical competency assessments.


Key Features

  • Electronic Feedback System: Provides interactive guidance during selected intubation exercises.
  • Realistic Adult Airway: Recreates important oral, pharyngeal and tracheal structures for practical training.
  • Vocal-Cord Simulation: Helps learners understand the correct pathway for endotracheal tube placement.
  • Multiple Training Scenarios: Supports varied airway situations and selected intubation difficulties.
  • Laryngoscope Practice: Allows supervised use of suitable training laryngoscopes and airway tools.
  • Tube-Placement Training: Helps users practise tube insertion, advancement and positioning.
  • Stable Training Base: Keeps the head and torso secure during hands-on practice.
  • Durable Construction: Designed for repeated institutional training when handled correctly.

Technical Specifications

Specification Details
Product Type Electronic Tracheal Intubation Training Manikin
Body Design Adult Head, Neck and Upper-Torso Model
Training Focus Airway Assessment and Endotracheal Intubation Practice
Feedback Type Electronic Guidance and Interactive Training Feedback
Airway Structures Mouth, Tongue, Throat, Vocal-Cord Region and Tracheal Pathway
Training Scenarios Standard and Selected Difficult Intubation Situations
Supported Procedure Oral Endotracheal Intubation Training
Construction Durable Medical Simulation Material
Product Dimensions 44 × 31 × 24 cm
Product Height 24 cm
Product Width 31 cm
Approx. Weight 10 kg
Usage Medical Education, Anaesthesia Training and Clinical Simulation
Suitable For Medical Colleges, Hospitals, Nursing Institutes and Simulation Labs

Benefits

  • Helps learners practise intubation without placing a patient at risk.
  • Therefore, students can repeat difficult steps until their control improves.
  • Also, electronic guidance supports faster correction during practice.
  • In addition, the vocal-cord area improves airway-pathway understanding.
  • Moreover, different scenarios support progressive skill development.
  • As a result, instructors can use the model for teaching and assessment.
  • Finally, the stable design supports organised classroom training.

Suitable For

  • Medical colleges and teaching hospitals
  • Nursing and paramedical institutes
  • Anaesthesia and emergency departments
  • Clinical skills and simulation laboratories
  • Airway-management training programmes

Applications

  • Oral endotracheal intubation practice
  • Airway assessment demonstrations
  • Laryngoscope handling training
  • Vocal-cord identification practice
  • Difficult-airway scenario training
  • Clinical competency assessment

Why Choose This Intubation Manikin?

This intubation manikin combines realistic airway anatomy with electronic training support. For example, learners can position the head, insert a laryngoscope and guide the tube towards the simulated vocal cords. Consequently, instructors can assess the complete procedure in a structured way.

The model also supports repeated practice in selected airway situations. In addition, its adult upper-torso design provides a practical working position. Therefore, it is useful for medical colleges, hospitals and simulation centres that conduct regular airway-management training.

Buying Guidance

Before buying, confirm that your course requires electronic feedback and difficult-airway practice. Also, check compatibility with your laryngoscopes, endotracheal tubes and training equipment. Finally, verify the exact electronic functions, power requirements and supplied configuration before ordering.

Usage Note: Use this model only for supervised education and simulation. Use suitable training airway equipment and follow the supplied cleaning instructions. The manikin cannot replace approved airway courses, professional certification or supervised clinical experience.

FAQs

1. What is this intubation manikin used for?

It is used for airway assessment, laryngoscope handling and oral endotracheal intubation training.

2. Does the model provide electronic feedback?

Yes. It provides interactive guidance during selected training procedures.

3. Does it simulate vocal cords?

Yes. The airway includes a simulated vocal-cord region for tube-placement practice.

4. Can learners practise difficult intubation scenarios?

Yes. The model supports selected levels of intubation difficulty.

5. What are the dimensions and weight?

The model measures approximately 44 × 31 × 24 cm and weighs around 10 kg.

6. Is it suitable for medical colleges?

Yes. Medical colleges, hospitals and simulation laboratories can use it.

7. Can this model replace clinical airway training?

No. However, it helps prepare learners for supervised clinical practice.