Vendeur: MeddeyGo.com

Boyle’s Apparatus Anaesthesia Machine SS with 4 Cylinders

882,99 €1 747,11 €49% OFF
size: with Vaporiser
Quantité

Détails du produit

The Boyle's Apparatus Anaesthesia Machine in stainless steel is a professional continuous flow anaesthesia workstation. Anaesthetists and operation theatre teams use it to deliver a controlled and precise mixture of anaesthetic gases and oxygen to patients during surgical procedures. Because it supports 4 gas cylinders, it accommodates the gas configurations required for general anaesthesia in hospital operation theatres.

Moreover, the stainless steel construction provides durability and ease of surface disinfection in surgical environments. As a result, the machine maintains hygiene standards required for operation theatre use. Therefore, it forms a reliable and clinically appropriate anaesthesia apparatus for hospitals, surgical centres, and operation theatre setups.

This anaesthesia workstation is suitable for the following clinical settings:

  • General surgery operation theatres in hospitals and nursing homes
  • Orthopaedic, gynaecology, and ENT surgical suites
  • Day surgery centres and multi-speciality hospitals
  • Teaching hospitals and medical college operation theatres

What Is a Boyle's Apparatus Anaesthesia Machine

A Boyle's apparatus is a type of continuous flow anaesthesia machine. It delivers a controlled and metered flow of medical gases — typically oxygen, nitrous oxide, and an inhalational anaesthetic agent — to the patient via a breathing circuit. Because gas flow rates are set precisely using calibrated flowmeters, the anaesthetist maintains exact control of the gas mixture throughout the procedure. Therefore, the Boyle's apparatus remains a standard anaesthesia workstation in Indian hospitals and operation theatres.

Furthermore, the Boyle's apparatus design supports the safe administration of inhalational anaesthesia. Because it integrates the gas supply system, flowmeters, vaporiser mount, and breathing circuit into a single mobile workstation, the anaesthetist manages all components from one location. As a result, this anaesthesia apparatus improves procedural organisation, reduces setup time, and supports safe anaesthesia delivery in clinical environments of varying complexity.

Key Features

Stainless Steel Construction

The machine uses stainless steel for the main frame and working surfaces. Stainless steel resists corrosion and withstands repeated surface disinfection with hospital-grade cleaning agents. Because operation theatre equipment requires rigorous infection control standards, the stainless steel build directly supports OT hygiene compliance. Furthermore, it provides structural durability for long-term use in demanding surgical environments.

Four-Cylinder Gas Supply Configuration

The apparatus supports four gas cylinders simultaneously. This configuration accommodates oxygen, nitrous oxide, and additional medical gas cylinders as required for different anaesthesia protocols. Because having multiple cylinders connected reduces the risk of gas interruption during a procedure, the 4-cylinder design improves safety and operational reliability. As a result, anaesthetists manage gas supply without interrupting the procedure.

Flowmeters and Gas Delivery System

Calibrated flowmeters allow precise measurement and control of each gas flow rate during anaesthesia administration. Because accurate gas flow directly affects the depth and safety of anaesthesia, calibrated flowmeters are a critical component of any anaesthesia workstation. Therefore, the Boyle's apparatus delivers the controlled gas mixture that safe inhalational anaesthesia requires throughout each procedure.

Breathing Circuit and Vaporiser Mount

The apparatus includes a breathing circuit for patient gas delivery and a vaporiser mount for inhalational anaesthetic agents. Because the breathing circuit connects the gas delivery system directly to the patient's airway, it forms an essential part of the complete anaesthesia apparatus setup. Furthermore, the vaporiser mount supports attachment of standard vaporiser units, which consequently allows the machine to deliver volatile anaesthetic agents as part of a complete anaesthesia protocol.

Mobile Trolley Base with Castors

The machine mounts on a mobile trolley base with lockable castors. Because operation theatre layouts vary and equipment often needs repositioning between procedures, the mobile base improves workflow flexibility. As a result, the anaesthesia apparatus moves easily within the OT and locks securely in position during surgery. Therefore, the design supports both procedural safety and OT operational efficiency.

Technical Specifications

Specification Details
Product Name Boyle's Apparatus Anaesthesia Machine SS with 4 Cylinders
Construction Stainless Steel (SS) Frame and Work Surface
Cylinder Configuration 4 Cylinders (Oxygen, Nitrous Oxide and Medical Gases)
Height 152 cm
Width 65 cm
Depth 60 cm
Mobility Mobile Trolley Base with Lockable Castors
Gas Delivery Calibrated Flowmeters for Precise Gas Flow Control
Breathing Circuit Integrated Breathing Circuit for Patient Gas Delivery
Vaporiser Vaporiser Mount for Inhalational Anaesthetic Agents
Ideal For Hospitals, Operation Theatres, Surgical Centres, Medical Colleges

Clinical Applications and Uses

The Boyle's apparatus anaesthesia machine suits all surgical settings that require general inhalational anaesthesia. Because it delivers a complete and controlled anaesthesia gas supply system in a single mobile unit, it meets the requirements of operation theatres across multiple surgical specialities.

General Surgery Operation Theatres

General surgery departments use the Boyle's apparatus as a standard anaesthesia workstation for routine elective and emergency surgical procedures. Because the 4-cylinder configuration handles the gas volumes required for extended procedures, it suits both short and long-duration surgeries. As a result, anaesthesia teams rely on it for consistent and safe gas delivery across a full surgical list.

Orthopaedic, Gynaecology and ENT Surgical Suites

Surgical specialities including orthopaedics, gynaecology, and ENT use the Boyle's apparatus for their respective procedure requirements. Because these specialities involve both short and extended surgical cases under general anaesthesia, the flexible gas delivery system and vaporiser mount accommodate a range of anaesthetic protocols. Furthermore, the mobile base allows easy positioning within speciality OT layouts.

Medical Colleges and Teaching Hospitals

In addition, medical college operation theatres and teaching hospitals use the Boyle's apparatus for both clinical procedures and anaesthesia training. Because anaesthesia residents and medical students must learn to set up and operate anaesthesia workstations as part of their clinical education, this apparatus provides the hands-on training platform they require. Consequently, it serves both an active clinical function and a teaching role in academic hospital settings.

Clinical Context and Professional Standards

The Boyle's apparatus is a long-established anaesthesia workstation design that remains in widespread use in Indian hospitals. Moreover, the Central Drugs Standard Control Organisation (CDSCO) and the Bureau of Indian Standards (BIS) regulate medical gas equipment and anaesthesia apparatus standards in India. Because anaesthesia machine safety directly affects patient outcomes during surgery, compliance with applicable equipment standards is a non-negotiable requirement for clinical use.

Furthermore, the Indian Society of Anaesthesiologists (ISA) provides professional guidelines on anaesthesia equipment standards, pre-use safety checks, and maintenance protocols for anaesthesia workstations. Because correct setup, calibration, and maintenance of the Boyle's apparatus directly affect patient safety, institutions must ensure that all anaesthesia machines undergo regular servicing. Therefore, procurement of anaesthesia apparatus should always include a maintenance and calibration plan.

Professional Use Notice This Boyle's apparatus anaesthesia machine is for use by qualified anaesthetists and trained operation theatre staff only. Furthermore, all anaesthesia machines must undergo pre-use safety checks before each procedure, in accordance with the guidelines of the Indian Society of Anaesthesiologists (ISA) and the institution's OT safety protocols. Installation and commissioning should be carried out by a qualified biomedical engineer.

Why Choose MeddeyGo

MeddeyGo is a trusted platform for professional operation theatre and anaesthesia equipment in India. Because we source products from verified manufacturers and authorised supply channels, we provide hospitals and surgical centres with reliable anaesthesia apparatus at competitive prices.

Clinically Suitable OT Equipment

Every product listed on MeddeyGo undergoes review for clinical and technical suitability. As a result, hospital procurement teams can be confident they purchase equipment appropriate for operation theatre use. Moreover, we provide full technical specifications and transparent product information to support informed procurement decisions.

Support for Hospital and Bulk Orders

MeddeyGo supports procurement for hospitals, surgical centres, nursing homes, and medical colleges. Therefore, we offer institutional pricing, documentation assistance, and dedicated account management for bulk buyers. Consequently, procurement teams complete their orders efficiently and with the paperwork required for hospital purchase processes.

Delivery and After-Sales Support

Our team dispatches orders with packaging appropriate for medical equipment. Furthermore, our after-sales team assists with delivery coordination, installation queries, and warranty matters. As a result, hospitals receive dependable support from purchase through to commissioning.

Frequently Asked Questions (FAQs)

About the Machine and Its Components

What is a Boyle's apparatus anaesthesia machine? A Boyle's apparatus is a continuous flow anaesthesia workstation. Anaesthetists use it to deliver a controlled mixture of anaesthetic gases and oxygen to patients during surgical procedures. Because it integrates gas cylinders, flowmeters, a vaporiser mount, and a breathing circuit into one mobile unit, it provides a complete anaesthesia gas delivery system. Therefore, it forms a standard anaesthesia apparatus in Indian operation theatres.
Why is stainless steel used for the anaesthesia machine frame?
Stainless steel resists corrosion and tolerates repeated disinfection with hospital-grade cleaning agents. Because operation theatre equipment faces rigorous infection control requirements, stainless steel construction directly supports OT hygiene compliance. Furthermore, it provides long-term structural durability in demanding surgical environments. As a result, stainless steel is the preferred material for operation theatre equipment frames and surfaces.
What gases does this 4-cylinder Boyle's apparatus support?
This apparatus supports 4 cylinders, typically configured for oxygen, nitrous oxide, and additional medical gases as required by the anaesthesia protocol. Because having multiple cylinders connected reduces the risk of gas interruption during surgery, the 4-cylinder design improves procedural safety. Furthermore, the configuration accommodates the gas supply requirements of both short and extended surgical cases.

About Setup, Dimensions and Use

What are the dimensions of this Boyle's anaesthesia machine? This Boyle's apparatus measures 65 cm in width, 60 cm in depth, and 152 cm in height. Because operation theatre space planning requires accurate equipment dimensions, hospital biomedical and OT teams should confirm that the machine fits within the designated anaesthesia workstation area before ordering. Therefore, MeddeyGo recommends reviewing OT floor plans and dimensions before purchase.
Does this anaesthesia machine require professional installation?
Yes. A qualified biomedical engineer must install and commission this Boyle's apparatus before clinical use. Because gas connections, flowmeter calibration, and breathing circuit integrity all affect patient safety, professional installation is essential. Furthermore, the machine must undergo a pre-use safety check by the anaesthesia team before each surgical session, in accordance with ISA guidelines. Therefore, the institution's biomedical department should coordinate installation on delivery.
Who should operate this Boyle's apparatus?
Only qualified anaesthetists and trained operation theatre staff should operate this anaesthesia workstation. Because incorrect setup or use of anaesthesia equipment can directly affect patient safety during surgery, operation of the Boyle's apparatus requires specialist clinical training. Furthermore, institutions should ensure all operating staff complete the relevant anaesthesia equipment training before using this apparatus in clinical practice.

About Ordering and After-Sales

Is this Boyle's apparatus available for bulk hospital orders? Yes. MeddeyGo supports bulk purchasing for hospitals, surgical centres, nursing homes, and medical colleges. Because institutional orders for OT equipment often require specific documentation, coordinated delivery, and installation support, our team assists procurement departments throughout the process. Therefore, hospitals should contact MeddeyGo directly for bulk pricing, availability, and ordering details.